Liquid Immersed Power Transformer
plantAspect
IMF Block
Deprecated
Created 2024-12-10 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block Liquid Immersed Power Transformer in Plant aspect.
Identifier:
https://posccaesar.org/imf/blocks/967d62fa-87c9-454d-88d1-32dace13d1b0
Types:
Class
IMF Block
NodeShape
Is defined by:
IMF Type Library
Is replaced by:
Liquid Immersed Power Transformer
Attributes
(93)
Attributes
TANK_SURFACE_FINISH_TYPE
WINDING_INSULATION_CLASS
BIDIRECTIONAL_ROLLERS_REQUIREMENT
TRANSFORMER_COOLING_SYSTEM
FIBER_OPTIC_TEMPERATURE_SENSOR_CHANNEL_COUNT
TOLERANCE_PCT_ON_TOTAL_LOSSES
SUPPLY_VOLTAGE_HARMONIC_CONTENT_PCT
LIFTING_LUGS_REQUIREMENT
PAINTING_SPECIFICATION
BUSDUCT_TYPE
INSULATING_LIQUID_TYPE
COOLING_FAN_REQUIREMENT
DISSOLVED_GASSES_MEASUREMENT_IN_DIELECTRIC_LIQUIDS_REQUIRED
LIQUID_LEVEL_INDICATOR_REQUIREMENT
DIRECTION_OF_POWER_FLOW
RADIATORS_SURFACE_FINISH_TYPE
CURRENT_TRANSFORMER_RATIO
WINDING_TEMP_SENSOR_TYPE
MECHANICAL_TEST_REQUIRED
PAINT_COLOUR
PARENT_TAG
VOLTAGE_AND_FREQUENCY_RATIO_VARIATION_PCT
MARSHALLING_BOX_REQUIREMENT
WINDING_TEMPERATURE_RISE
COUNT
TERTIARY_RATED_VOLTAGE
VECTOR_GROUP
SUDDEN_PRESSURE_RELAY_REQUIREMENT
THERMALLY_UPGRADED_PAPER_REQUIREMENT
OPERATIONAL_MODE
ROUTINE_TEST_FOR_EX_P_TYPE_TRANSFORMER_REQUIRED
VACUUM_DEFLECTION_TEST_REQUIRED
TRANSIENT_VOLTAGE_TRANSFER_CHARACTERISTICS_DETERMINATION_REQUIRED
IMPACT_RECORDER_REQUIREMENT_DURING_TRANSPORTATION
SHORTCIRCUIT_WITHSTAND_TEST_REQUIRED
WINDING_TO_WINDING_CAPACITANCE_MEASUREMENT_REQUIRED
SURFACE_PROTECTION_CORROSIVITY_CATEGORY
INSULATING_LIQUID_TEMPERATURE_RISE
LIQUID_PRESERVATION_SYSTEM_TYPE
TEMPERATURE_RISE_TEST_REQUIRED
CURRENT_TRANSFORMER_BURDEN
WINDING_HOT_SPOT_TEMPERATURE_RISE_MEASUREMENTS_REQUIRED
SIMULATED_ON_LOAD_START_TEST_REQUIRED
TOLERANCE_PCT_ON_IMPEDANCE_VALUE
COVER_TYPE
OVERLOADING_REQUIREMENT
ZERO_SEQUENCE_IMPEDANCE_LOWER_LIMIT
TAP_CHANGER_REQUIREMENT
SUPPLIER
MAGNETIC_LIQUID_LEVEL_GAUGE_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
SURGE_ARRESTER_REQUIREMENT
FANS_AND_LIQUID_PUMP_MOTORS_POWER_CONSUMPTION_TEST_REQUIRED
NOLOAD_LOSS_AND_CURRENT_MEASUREMENT_AT_90PCT_AND_110PCT_RATED_VOLTAGE_REQUIRED
REQUIREMENT_OF_FACILITY_FOR_LIQUID_EMISSIONS_FROM_RELIEF_DEVICE_IN_DIRECTION_SPECIFIED
STABILIZING_WINDING_EARTHING_TYPE
MAX_LIMIT_TRANSPORTATION_WIDTH
MAX_LIMIT_TRANSPORTATION_DEPTH
ZERO_SEQUENCE_IMPEDANCE_MEASUREMENT_REQUIRED
BUCHHOLZ_RELAY_WITH_ALARM_AND_TRIP_CONTACT_REQUIREMENT
SURGE_ARRESTER_CLASS
LIQUID_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
CORE_EARTHING_TERMINALS_AT_ACCESSIBLE_LOCATION_REQUIREMENT
CONFORMITY_ASSESSMENT_SYSTEM_CAS_LEVEL
CURRENT_TRANSFORMER_ACCURACY_CLASS
MAX_LIMIT_TRANSPORTATION_HEIGHT
FIBER_OPTIC_TEMPERATURE_SENSING_REQUIREMENT
DIELECTRIC_TYPE_TESTS_REQUIRED
VOLTAGE_VARIATION_SIDE
PRESSURE_DEFLECTION_TEST_REQUIRED
ROUTINE_TESTS_FOR_EX_O_TYPE_TRANSFORMER_REQUIRED
POWER_FACTOR_AT_100PCT_LOAD
LADDER_REQUIREMENT
MAX_LIMIT_TRANSPORTATION_WEIGHT
SILICA_GEL_BREATHER_REQUIREMENT_FOR_MAIN_TANK
SERVICE_DESCRIPTION
SOUND_LEVEL_TEST_REQUIRED
ONLINE_DISSOLVED_GAS_ANALYSIS_REQUIREMENT
VACUUM_TIGHTNESS_TEST_REQUIRED
FREQUENCY_RESPONSE_ANALYSIS_REQUIRED
HIGH_TEMPERATURE_INSULATION_REQUIREMENT
ALLOWED_SOUND_POWER_LEVEL_MAX
EXTERNAL_COATING_CHECKING_REQUIRED
ACCELERATION_ABOVE_1G_DURING_TRANSPORTATION
WINDING_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
NON_UNIFORM_INSULATION_REQUIREMENT
SHORT_CIRCUIT_APPARENT_POWER
PERCENTAGE_IMPEDANCE_ON_AN_RATING_AT_PRINCIPAL_TAP
CONSERVATOR_DIAPHRAGM_FAILURE_ALARM_CONTACT_REQUIREMENT
SILICA_GEL_BREATHER_TYPE
ZERO_SEQUENCE_IMPEDANCE_UPPER_LIMIT
PRESSURE_RELIEF_DEVICE_REQUIREMENT
WINDINGS_TO_EARTH_CAPACITANCE_MEASUREMENT_REQUIRED
DELTA_CONNECTED_STABILIZING_WINDING_REQUIREMENT
Sub blocks
(5)
HasPart
Transformer Winding
Tap Changer (incl. OLTC)
Cooling Fan
Termination Point
Transformer Winding
More info
(1)
Super classes
:
Block