Dry Type Power Transformer
plantAspect
IMF Block
Deprecated
Created 2024-12-10 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block Dry Type Power Transformer in Plant aspect.
Identifier:
https://posccaesar.org/imf/blocks/3d9fc912-5c73-46fd-a02b-d72d823817dd
Types:
NodeShape
Class
IMF Block
Is defined by:
IMF Type Library
Is replaced by:
Dry Type Power Transformer
Attributes
(89)
Attributes
TAP_CHANGER_REQUIREMENT
SHORTCIRCUIT_WITHSTAND_TEST_REQUIRED
STABILIZING_WINDING_EARTHING_TYPE
SUPPLY_VOLTAGE_HARMONIC_CONTENT_PCT
HIGH_TEMPERATURE_INSULATION_REQUIREMENT
THERMALLY_UPGRADED_PAPER_REQUIREMENT
MAX_LIMIT_TRANSPORTATION_DEPTH
ZERO_SEQUENCE_IMPEDANCE_MEASUREMENT_REQUIRED
CURRENT_TRANSFORMER_RATIO
VOLTAGE_VARIATION_SIDE
VOLTAGE_AND_FREQUENCY_RATIO_VARIATION_PCT
VIBRATION_LEVEL_TEST_REQUIREMENT
MANUFACTURER_MODEL_NO
WINDING_TO_WINDING_CAPACITANCE_MEASUREMENT_REQUIRED
POWER_FACTOR_AT_100PCT_LOAD
DIELECTRIC_TYPE_TESTS_REQUIRED
SURFACE_PROTECTION_CORROSIVITY_CATEGORY
COOLING_FAN_REQUIREMENT
FIRE_BEHAVIOR_CLASS
NON_UNIFORM_INSULATION_REQUIREMENT
TEMPERATURE_RISE_TEST_REQUIRED
VIBRATION_LEVEL
WINDINGS_TO_EARTH_CAPACITANCE_MEASUREMENT_REQUIRED
SIMULATED_ON_LOAD_START_TEST_REQUIRED
SHORT_CIRCUIT_IMPEDANCE
MANUFACTURER
CLIMATIC_CLASS
INSULATING_LIQUID_TEMPERATURE_RISE
WINDING_TEMPERATURE_RISE
OVERLOADING_REQUIREMENT
MAX_LIMIT_TRANSPORTATION_HEIGHT
SOUND_LEVEL_TEST_REQUIRED
EXTERNAL_COATING_CHECKING_REQUIRED
SUPPLIER
WINDING_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
TRANSFORMER_COOLING_SYSTEM
CONFORMITY_ASSESSMENT_SYSTEM_CAS_LEVEL
PAINT_COLOUR
ACCELERATION_ABOVE_1G_DURING_TRANSPORTATION
TAG_NO
TAPPING_AT_PRIMARY_SIDE
FANS_AND_LIQUID_PUMP_MOTORS_POWER_CONSUMPTION_TEST_REQUIRED
ENVIRONMENTAL_CLASS
SURGE_ARRESTER_CLASS
BUSDUCT_TYPE
MAX_LIMIT_TRANSPORTATION_WEIGHT
LIFTING_LUGS_REQUIREMENT
MAX_LIMIT_TRANSPORTATION_WIDTH
TOLERANCE_PCT_ON_IMPEDANCE_VALUE
NOLOAD_LOSS_AND_CURRENT_MEASUREMENT_AT_90PCT_AND_110PCT_RATED_VOLTAGE_REQUIRED
FUNCTIONAL_CLASS
SERVICE_DESCRIPTION
PAINTING_SPECIFICATION
PARENT_TAG
IP_GRADE
ZERO_SEQUENCE_IMPEDANCE_LOWER_LIMIT
TERTIARY_RATED_VOLTAGE
ALLOWED_SOUND_POWER_LEVEL_MAX
TEST_VOLTAGES_ACC_IEC_60076_LIST_2
CORE_EARTHING_TERMINALS_AT_ACCESSIBLE_LOCATION_REQUIREMENT
SHORT_CIRCUIT_CURRENT_RMS_VALUE
TYPE
PERCENTAGE_IMPEDANCE_ON_AN_RATING_AT_PRINCIPAL_TAP
TRANSIENT_VOLTAGE_TRANSFER_CHARACTERISTICS_DETERMINATION_REQUIRED
COUNT
LADDER_REQUIREMENT
ZERO_SEQUENCE_IMPEDANCE_UPPER_LIMIT
MARSHALLING_BOX_REQUIREMENT
FREQUENCY_RESPONSE_ANALYSIS_REQUIRED
OPERATIONAL_MODE
IMPACT_RECORDER_REQUIREMENT_DURING_TRANSPORTATION
TANK_SURFACE_FINISH_TYPE
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
VECTOR_GROUP
RADIATORS_SURFACE_FINISH_TYPE
SURGE_ARRESTER_REQUIREMENT
SHORT_CIRCUIT_CURRENT_PEAK_VALUE
WINDING_HOT_SPOT_TEMPERATURE_RISE_MEASUREMENTS_REQUIRED
CURRENT_TRANSFORMER_BURDEN
DIRECTION_OF_POWER_FLOW
WINDING_INSULATION_CLASS
TOLERANCE_PCT_ON_TOTAL_LOSSES
WINDING_TEMP_SENSOR_TYPE
BIDIRECTIONAL_ROLLERS_REQUIREMENT
DELTA_CONNECTED_STABILIZING_WINDING_REQUIREMENT
TEST_VOLTAGES_ACC_IEC_60076_LIST_1
TERMINAL_TYPE_FOR_EARTHING_APPARATUS
SHORT_CIRCUIT_APPARENT_POWER
CURRENT_TRANSFORMER_ACCURACY_CLASS
Sub blocks
(4)
HasPart
Tap Changer (incl. OLTC)
Transformer Winding
Termination Point
Cooling Fan
More info
(1)
Super classes
:
Block