AC Generator
productAspect
IMF Block
Submitted
Created 2025-01-23 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block AC Generator in Product aspect.
Identifier:
https://posccaesar.org/imf/blocks/ac6a74a5-6524-4b72-b2bb-cb1cbd302b1c
Types:
Class
IMF Block
NodeShape
Replaces:
AC Generator
Attributes
(112)
Attributes
DESIGN_STANDARD
DIRECT_AXIS_TRANSIENT_REACTANCE_UNSATURATED
FIELD_CURRENT_RATED_LOAD
DIRECT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
OVERLOAD_CAPABILITY_HOURS_DURATION
DIRECT_AXIS_OPEN_CIRCUIT_TRANSIENT_TIME_CONSTANT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
INSULATION_CLASS_STATOR
ZERO_PHASE_SEQUENCE_RESISTANCE
FRAME_SIZE
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
SUSTAINED_SHORTCIRCUIT_PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
TYPE
MANUFACTURER
MAX_ALLOWABLE_NEGATIVE_SEQUENCE_CURRENT
EFFICIENCY_AT_75PCT_LOAD
QUADRAT_AXIS_TRANSIENT_REACTANCE
BEARING_LUBRICATION_SYSTEM
TOTAL_WEIGHT
PAINTING_SPECIFICATION
EARTHING_SYSTEM
WINDING_TEMP_SENSOR_TYPE
BEARING_TEMP_DETECTORS_TYPE
THRUST_BEARING_COUNT
HEIGHT
THRUST_BEARING_TYPE
STATOR_WINDING_DC_RESISTANCE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
VIBRATION_DETECTOR_TYPE
DIRECT_AXIS_TRANSIENT_REACTANCE_SATURATED
VIBRATION_DETECTORS_COUNT
MOMENT_OF_INERTIA_PRIME_MOVER
FIELD_CURRENT_NO_LOAD
LEAKAGE_DETECTION_SYSTEM
LUBRICANT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
DC_TIME_CONSTANT
STATOR_WINDING_LEAKAGE_REACTANCE
SUSTAINED_SHORTCIRCUIT_DURATION
WINDING_TEMP_SENSOR_COUNT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
INSULATION_CLASS_ROTOR
POSITIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
HEAT_EXCHANGER_MATERIAL
VIBRATION_DETECTOR_REQUIRED
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
RATED_POWER
NEGATIVE_PHASE_SEQUENCE_REACTANCE_UNSATURATED
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
SOUND_PRESSURE_LEVEL_MAX
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
DIRECT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
NEGATIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
TEMPERATURE_RISE_CLASS_STATOR
EFFICIENCY_AT_100PCT_LOAD
NON_DRIVE_END_BEARING_COUNT
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_UNSATURATED
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
SPACE_HEATER_REQUIRED
POWER_FACTOR
HEAT_EXCHANGER_DRY_WEIGHT
COOLANT_WEIGHT
OVERLOAD_CAPABILITY_PCT_FOR_HOURS_DURATION
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_SATURATED
LUBE_OIL_PRESSURE
DIRECT_AXIS_SHORT_CIRCUIT_TRANSIENT_TIME_CONSTANT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
TEMPERATURE_RISE_CLASS_ROTOR
EXCITATION_SYSTEM_TYPE
QUADRAT_AXIS_SUBTRANSIENT_REACTANCE
LUBE_OIL_TEMP
COOLING_METHOD_IC
QUADRAT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
ROTOR_WEIGHT
LENGTH
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
BEARING_TEMP_DETECTORS_COUNT
DIRECT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
SYNCHRONOUS_SPEED
OVERLOAD_CAPABILITY_SECONDS_DURATION
IP_GRADE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
QUADRAT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
MOMENT_OF_INERTIA
ZERO_PHASE_SEQUENCE_REACTANCE_UNSATURATED
QUADRAT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
WIDTH
SHORT_CIRCUIT_RATIO
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
MAX_ALLOWABLE_TOTAL_HARMONIC_DISTORTION_THD_PCT
NON_DRIVE_END_BEARING_TYPE
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
NEGATIVE_PHASE_SEQUENCE_REACTANCE_SATURATED
DRIVE_END_BEARING_COUNT
DRIVE_END_BEARING_TYPE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
ROTOR_TYPE
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
ALLOWED_AXIAL_THRUST
EARTH_FAULT_CURRENT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
OVERLOAD_CAPABILITY_PCT_FOR_SECONDS_DURATION
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
DUTY_TYPE
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
WINDING_TEMPERATURE_DETECTION_REQUIRED
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
Terminals
(2)
HasTerminal
MediaFlowConnection
MechanicalEnergyConnection
Sub blocks
(2)
HasPart
Exciter
Terminal Box
More info
(1)
Super classes
:
Block