AC Generator
productAspect
Class
IMF Block
Submitted
Created 2025-01-23 by
[email protected]
Information
Graph
History
Definition
IMF Type Block AC Generator in Product aspect.
Identifier:
https://posccaesar.org/imf/blocks/ac6a74a5-6524-4b72-b2bb-cb1cbd302b1c
Replaces:
AC Generator
Attributes
(112)
ALLOWED_AXIAL_THRUST
BEARING_LUBRICATION_SYSTEM
BEARING_TEMP_DETECTORS_COUNT
BEARING_TEMP_DETECTORS_TYPE
COOLANT_WEIGHT
COOLING_METHOD_IC
DC_TIME_CONSTANT
DESIGN_STANDARD
DIRECT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
DIRECT_AXIS_OPEN_CIRCUIT_TRANSIENT_TIME_CONSTANT
DIRECT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
DIRECT_AXIS_SHORT_CIRCUIT_TRANSIENT_TIME_CONSTANT
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_SATURATED
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_UNSATURATED
DIRECT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
DIRECT_AXIS_TRANSIENT_REACTANCE_SATURATED
DIRECT_AXIS_TRANSIENT_REACTANCE_UNSATURATED
DRIVE_END_BEARING_COUNT
DRIVE_END_BEARING_TYPE
DUTY_TYPE
EARTH_FAULT_CURRENT
EARTHING_SYSTEM
EFFICIENCY_AT_100PCT_LOAD
EFFICIENCY_AT_75PCT_LOAD
EXCITATION_SYSTEM_TYPE
FIELD_CURRENT_NO_LOAD
FIELD_CURRENT_RATED_LOAD
FRAME_SIZE
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
HEAT_EXCHANGER_DRY_WEIGHT
HEAT_EXCHANGER_MATERIAL
HEIGHT
INSULATION_CLASS_ROTOR
INSULATION_CLASS_STATOR
IP_GRADE
LEAKAGE_DETECTION_SYSTEM
LENGTH
LUBE_OIL_PRESSURE
LUBE_OIL_TEMP
LUBRICANT
MANUFACTURER
MAX_ALLOWABLE_NEGATIVE_SEQUENCE_CURRENT
MAX_ALLOWABLE_TOTAL_HARMONIC_DISTORTION_THD_PCT
MOMENT_OF_INERTIA
MOMENT_OF_INERTIA_PRIME_MOVER
NEGATIVE_PHASE_SEQUENCE_REACTANCE_SATURATED
NEGATIVE_PHASE_SEQUENCE_REACTANCE_UNSATURATED
NEGATIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
NON_DRIVE_END_BEARING_COUNT
NON_DRIVE_END_BEARING_TYPE
OVERLOAD_CAPABILITY_HOURS_DURATION
OVERLOAD_CAPABILITY_PCT_FOR_HOURS_DURATION
OVERLOAD_CAPABILITY_PCT_FOR_SECONDS_DURATION
OVERLOAD_CAPABILITY_SECONDS_DURATION
PAINTING_SPECIFICATION
POSITIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
POWER_FACTOR
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
QUADRAT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
QUADRAT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
QUADRAT_AXIS_SUBTRANSIENT_REACTANCE
QUADRAT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
QUADRAT_AXIS_TRANSIENT_REACTANCE
RATED_POWER
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
ROTOR_TYPE
ROTOR_WEIGHT
SHORT_CIRCUIT_RATIO
SOUND_PRESSURE_LEVEL_MAX
SPACE_HEATER_REQUIRED
STATOR_WINDING_DC_RESISTANCE
STATOR_WINDING_LEAKAGE_REACTANCE
SUSTAINED_SHORTCIRCUIT_DURATION
SUSTAINED_SHORTCIRCUIT_PCT
SYNCHRONOUS_SPEED
TEMPERATURE_RISE_CLASS_ROTOR
TEMPERATURE_RISE_CLASS_STATOR
THRUST_BEARING_COUNT
THRUST_BEARING_TYPE
TOTAL_WEIGHT
TYPE
VIBRATION_DETECTOR_REQUIRED
VIBRATION_DETECTOR_TYPE
VIBRATION_DETECTORS_COUNT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
WIDTH
WINDING_TEMP_SENSOR_COUNT
WINDING_TEMP_SENSOR_TYPE
WINDING_TEMPERATURE_DETECTION_REQUIRED
ZERO_PHASE_SEQUENCE_REACTANCE_UNSATURATED
ZERO_PHASE_SEQUENCE_RESISTANCE
Reference terms
(0)
No reference terms
Terminals
(2)
MechanicalEnergyConnection
MediaFlowConnection
Sub blocks
(2)
Exciter
Terminal Box
More info
(1)
subClassOf
:
Block